ELISA Pro: Human apoH

ELISA Pro: Human apoH

3711-1HP-1

Publications: 4
Documents
Questions?
Thoroughly validated and include every buffer necessary, for a reliable and reproducible assay.

Components

PlatePre-coated ELISA strip plate (mAb H219)
Detection mAbH464, biotin
Enzyme conjugateStreptavidin-HRP
StandardNative human apoH ELISA standard
SubstrateELISA substrate: TMB for HRP
Buffers/SolutionsApo ELISA buffer concentate
Standard reconstitution buffer
Streptavidin-HRP diluent
Wash buffer concentrate
Stop solution
Also providedAdhesive plate covers

In stock

Delivery 4-9 business days

Shipping $0

Product specifications

Intended use

This ELISA Pro kit is intended for the quantification of human apoH in serum, plasma, and cell culture supernatants. For research use only. Not for use in diagnostic procedures.

Serum/Plasma samples

The Apo ELISA buffer included in this kit blocks heterophilic antibodies from cross-linking the assay antibodies, thereby preventing false-positive read-outs. Heterophilic antibodies are commonly found in human serum/plasma and can also be present in other species. The Apo ELISA buffer has been validated using serum/plasma samples from healthy human blood donors.

Apolipoprotein dilution
Apolipoproteins are present at high levels in serum and plasma. For ELISA quantification, such samples must therefore be diluted 5,000-200,000 times depending on the apolipoprotein analyzed.

Recommendation

Product details

ProductELISA Pro: Human apoH
ApplicationELISA
AnalyteapoH
ReactivityHuman, Non-human primates
Specificity

This kit is based on a matched pair of mAbs specific for human apoH.

Cross-reactivity

The mAbs react with human apoH and cross-react with apoH from non-human primates (NHP). For more information please check the Cross-reactivity guide section below.

Shipping and Storage

Shipping

Shipped at ambient temperature.

Storage

Store detection mAb, Streptavidin-HRP, buffers/solutions, and substrate at 4-8 °C upon receipt. The ELISA standard should be stored at -20 °C. Plates may be kept at room temperature.

Shelf lifeAt least 12 months from date of receipt.
Standard range0.02-15 ng/ml
Sensitivity0.02 ng/ml

The lowest concentration that can be detected, but not necessarily quantified with precision and accuracy. This was determined by adding 5 standard deviations to the mean OD of background wells.

Mean standard curve from repeated runs of human apoH ELISA Pro kit.

The systems reactive with NHPs are either based on cross-reactive human kits or specifically developed monkey kits (NHP).

Cross-reactivity verification tests have been performed in ELISpot and/or ELISA by Mabtech and/or by others. Evaluations of assays with less solid evidence of cross-reactivity are shown as symbols within parentheses.

 Rhesus MacaqueCynomolgus MacaquePig-tailed MacaqueBaboon*Sooty MangabeyAfrican Green MonkeyNight Monkey*Common MarmosetSquirrel Monkey
ASSAYOld worldNew world
ApoA1      
ApoB       
ApoE (NHP)       
ApoE       
ApoH       
CCL2 (MCP-1)       
CCL4 (MIP-1β) ( ) ( )( )( )( )
CCL22 (MDC) ( ) ( )( )( )( )
CD25       
GM-CSF( )( )   
Granzyme A        
Granzyme B (NHP)       
Granzyme B     
IFN-α2        
IFN-α pan   ( )   
IFN-γ (NHP)
IFN-γ( )
IgA (NHP)       
IgA       
IgG       
IgM       
INS     
IL-1α        
IL-1β        
IL-2 (NHP)
IL-3       
IL-4( )( )( )( )
IL-5( )( )( ) 
IL-6( )( ) ( ) 
IL-8 (NHP)        
IL-8 (ELISA)        
IL-8 (ELISpot)        
IL-10 (NHP)      
IL-10       
IL-12/-23 (p40)      
IL-12 (p70)        
IL-13 (NHP)( )( )( )  
IL-13        
IL-17A (NHP)( )( )   
IL-17A     
IL-17F        
IL-17A/F        
IL-21      
IL-22        
IL-23     
IL-27        
IL-31        
IP-10       
Perforin( )   
TGF-β1 (latent)       
TNF-α (NHP)( )  ( )( )( )( )
          
SINGLE mAbs         
Cell stimulation         
CD3, mAb CD3-1       
CD3, mAb CD3-2       
CD28, mAb CD28-A       
Flow cytometry          
IFN-γ mAb 1-D1K( )( )( )( )( )( )
IL-2 mAb MT8G10( )( )( )( ) ( )( )( )
IL-4 mAb IL4-3( )       
IL-17A mAb MT504        
Perforin mAb Pf-344     
TNF-α mAb MT15B15       
Ig reagents         
IgG1 mAb MTG1218       
IgG1 mAb MT1939       
IgG2 mAb H6200       
IgG2 mAb MTG211E       
IgG3 mAb MTG34       
IgG4 mAb MTG42       
Western blot         
IFN-γ mAb MT111W( )( )( )( )( )( )( )( )( )
TNF-α mAb MT15B15( )( )( )  ( )( )( )( )

Symbol keys:


Cross-reactivity

Verified by Mabtech and/or by others. Tests performed in ELISpot and/or ELISA.

  • good
  • poor
  • no

Indications of Cross-reactivity

Based on reports from others or by analysis using recombinant proteins.

  • ( ) good
  • ( ) poor
  • ( ) no

Monkey kits

Specifically developed monkey kits are marked with (NHP).

Blank boxes

Represent cross-reactivities not evaluated.

* Comprises several species. Cross-reactivity may have to be verified on a species basis.

Tutorial, Published July 31, 2023

ELISA publications by sample type
Find out how researchers have used our ELISAs to analyze different types of samples.
Loading publications...

apoH

Analyte description

Apolipoprotein H (apoH) is associated to VLDL, HDL, and chylomicrons in plasma and binds to anionic lipids e.g., phospholipids. ApoH is the dominant target of autoantibodies in anti-phospholipid syndrome (APS). In the blood coagulation pathway, apoH is involved both as an anti-coagulant and as a procoagulant. The normal concentration of apoH in human plasma is approximately 0.05-0.6 g/L.

Alternative namesApolipoprotein H, apoH, apolipoproteinH, apo H, beta 2-glycoprotein 1, β2-glycoprotein I, B2G1, B2GP1, BG
Gene ID350